Blog Contact
×

MPB 2-valve manifold for flanged instruments

DESCRIPTION

The MPB model is used to mount d/p cell style static pressure transmitters.

CHARACTERISTICS

• In this flanged version, the instrument is fixed with screws to one of the manifold faces and the process connection is 1/2” NPT threaded.
• It admits the usage of the SM bracket to mount to a 2” pipestand.

Datasheet

Assembly sheet

Specifications

Service pressure @ 70 °F:

6000 psi - Standard
4500 psi - AISI 316 SS mounting bolt

Maximum temperatures:

500 °F - PTFE packing
930 °F - Graphoil packing

Product code Connection 1 Connection 2 Model MWP (PSI) cv Quote
102104 FLANGE 1/2 NPT F MPB IT 6000
102114 FLANGE 1/2 NPT F MPB IG 6000